Customization: | Available |
---|---|
Usage: | Electric Component Tester, Gas Sensor Tester, Catalytic Element Tester, Lightning Protection Device Tester |
Environment: | Room Temperature |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
https://ckt2017.en.made-in-china.com/contact-info.html
Technical Parameter
Model | TH2840AX | TH2840BX | TH2840NX | |
Display | Display | 10.1" Captive Touch Screen | ||
Ratio | 16:09 | |||
Resolution | 1280×RGB×800 | |||
Test PIN | 20PIN(By TH1806) | 48PIN(Can extend to 288PIN) | ||
Frequency | Range | 20Hz-500kHz | 20Hz-2MHz | 20Hz-500kHz |
Accuracy | 0.01% | |||
Resolution | 0.1mHz (20.0000Hz-99.9999Hz) | |||
1mHz (100.000Hz-999.999Hz) | ||||
10mHz (1.00000kHz-9.99999kHz) | ||||
100mHz (10.0000kHz-99.9999kHz) | ||||
1Hz (100.000kHz-999.999kHz ) | ||||
10Hz (1.00000MHz-2.00000MHz) | ||||
AC test signal mode | Rated value (ALC OFF) | Set the voltage as the Hcur voltage when the test terminal is open | ||
Set the current to be the current flowing from Hcur when the test terminal is short-circuited | ||||
Constant value (ALC ON) | Keep the voltage on the DUT the same as the set value | |||
Keep the current on the DUT the same as the set value | ||||
Test Level | AC Voltage | 5mVrms-20Vrms | F<=1MHz 5mVrms-20Vrms | 5mVrms-20Vrms |
F>1MHz 5mVrms-15Vrms | ||||
Accuracy | ±(10%×the set value+2mV)(AC<=2Vrms) | |||
±(10%×the set value+5mV)(AC>2Vrms) | ||||
Resolution | 1mVrms (5mVrms-0.2Vrms) | |||
1mVrms (0.2Vrms-0.5Vrms) | ||||
1mVrms (0.5Vrms-1Vrms) | ||||
10mVrms (1Vrms-2Vrms) | ||||
10mVrms (2Vrms-5Vrms) | ||||
10mVrms (5Vrms-10Vrms) | ||||
10mVrms (10Vrms-20Vrms) | ||||
AC Current | 50μArms-100mArms | |||
Resolution(100Ω Internal Resistance) |
10μArms (50μArms-2mArms) | |||
10μArms (2mArms-5mArms) | ||||
10μArms (5mArms-10mArms) | ||||
100μArms (10mArms-20mArms) | ||||
100μArms (20mArms-50mArms) | ||||
100μArms (50mArms-100mArms) | ||||
RDC Test | Voltage | 100mV-20V | ||
Resolution | 1mV (0V-1V) | |||
10mV (1V-20V) | ||||
Current | 0mA-100mA | |||
Resolution | 10μA (0mA-10mA) | |||
100μA (10mA-100mA) | ||||
DC Bias * | Voltage | 0V-±40V | ||
Accuracy | AC<=2V 1%×the set voltage+5mV | |||
AC>2V 2%×the set voltage+8mV | ||||
Resolution | 1mV (0V - ±1V) | |||
10mV (±1V - ±40V) | ||||
Current | 0mA-±100mA | |||
Resolution | 10μA (0mA-10mA) | |||
100μA (10mA-100mA) | ||||
Built-in current source | Current | 0mA-2A | ||
Accuracy | I>5mA ±(2%×the set value+2mA) | |||
Resolution | 1mA | |||
Output impedance | 30Ω, ±4%@1kHz | |||
100Ω, ±2%@1kHz | ||||
LCR Function | ||||
Test Parameter | Method | Arbitrary selection of four parameters | ||
AC | Cp/Cs, Lp/Ls, Rp/Rs, |Z|, |Y|, R, X, G, B, θ, D, Q, VAC, IAC | |||
DC | RDC, VDC, IDC | |||
Test Terminal Configuration | Four Terminal Pair | |||
Test Cable Length | 0m | |||
Computation | The absolute deviation from the nominal value Δ, the percentage deviation from the nominal value Δ% | |||
Equivalent Way | Series, Parallel | |||
Calibration Function | OPEN, SHORT, LOAD | |||
Average Times | 1-255 | |||
Range Selection | AUTO, HOLD | |||
Range Configuration | LCR | 100mΩ, 1Ω, 10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10kΩ, 20kΩ, 50kΩ, 100kΩ | ||
RDC | 1Ω, 10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10kΩ, 20kΩ, 50kΩ, 100kΩ | |||
Test Speed (ms) | Fast+: 1ms. Fast: 3.3ms. Middle: 90ms. | |||
Slow: 220ms | ||||
Highest accuracy | 0.05% Please refer to the manuals for the details | |||
Measurement display range | ||||
Cs, Cp | 0.00001pF-9.99999F | |||
Ls, Lp | 0.00001μH-99.9999kH | |||
D | 0.00001-9.99999 | |||
Q | 0.00001-99999.9 | |||
R, Rs, Rp, X, Z, RDC | 0.001mΩ-99.9999MΩ | |||
G, B, Y | 0.00001μs-99.9999S | |||
VDC | ±0V-±999.999V | |||
IDC | ±0A-±999.999A | |||
θr | -6.28318 | |||
θd | -179.999°-179.999° | |||
Δ% | ±(0.000%-999.9%) | |||
TurnsRatio | 1:0.001-1000:1 | |||
Transformer Test | ||||
Test Parameter | Cs/Cp, Ls/Lp, DCR, Zx, Rs/Rp, D, Q, dZ, , Lk, Phase, Balance Turns-Ratio, Ns:Np=U2/U1, Np:Ns=U1/U2 Turns: Ns=Np×U2/U1, Np=Ns×U1/U2 |
|||
Test Mode | Continous | In the single trigger mode, manually trigger once, and once test all the test parameters. | ||
Step | In the single trigger mode, manually trigger once to measure one parameter. Trigger again to measure the next parameter. | |||
Test Speed (ms) | Fast | Fast: 3.3ms, Fast+ 0.56ms(>10kHz) | ||
Middle | Middle: 90ms | |||
Slow | Slow: 220ms | |||
Bias Resource | See * | |||
Average Times | Each test parameter can set different average times, the average times is 0-255 | |||
Time Delay | Each test parameter can set a different delay time | |||
Transformer Scanning | ||||
Built in Scanning Board | No | One Board as standard. Could extend to six boards. ((24×2)PIN per board) | ||
Transformer Handler | PIN Definition | NS1-NS30, GOOD, NG, TEST, TRIGGER, RESET | NS1-NS9, GOOD, NG, TEST, TRIGGER, RESET | |
Output characteristics | Optocoupler isolation, ULN2003 drive enhancement, collector output | |||
Model | Direct reading, percentage | |||
Test Range | Auto, Hold | |||
Bias Resource | See * | |||
External scanning box | compatible to TH1901 series, TH1831 scanning box, TH1806 series | |||
Number of windings | Primary | 60 | ||
Secondary | 9 | |||
Average Times | Each test parameter can set different average times, the average times is 0-255 | |||
Time Delay | Each test parameter can set a different delay time | |||
Test Speed (ms) | Fast | Fast: 3.3ms(>=1kHz). Fast+ : 0.56ms(>=10kHz) (Exclude the time for the realy action) | ||
Middle | Middle: 90ms | |||
Slow | Slow: 220ms | |||
Test lead interface | 25*2pin FRC socket | |||
Other Functions and specifications | ||||
Storage | Internal | About 100M non-volatile memory test setting file | ||
U Disk | Test setting file, screenshot graph, record file | |||
Keyboard Lock | The front panel keys can be locked | |||
Interface | USB HOST | 2 USB HOST ports. Mouse and keyboard could work at the same time. Only one U disk can be used at the same time. | ||
USB DEVICE | Universal serial bus socket, small type B (4 contact positions); compatible with USB TMC-USB488 and USB2.0, the female connector is used to connect an external controller. | |||
LAN | 10/100M Ethernet adaptive, 8 Pin | |||
HANDLER | Used for Bin signal output | |||
External DC BIAS Control | Support TH1778A (do not support transformer scanning) | |||
RS232C | Standard 9-pin, cross | |||
RS485 | Can accept modification or connect to RS232 to RS485 adaptor | |||
Power-on Warm-up Time | 60 Minutes | |||
Output Voltage | 100-120VAC/198-242VAC Optional, 47-63Hz | |||
Power Consumption | More than 130VA | |||
Size (WxHxD) mm | 430mm(W)x177mm(H)x265mm(D) | 430mm(W)x177mm(H)x405mm(D) | ||
Weight (kg) | 11kg | 17kg |
Chuangkai Electronic Co., Ltd is leading company specialized in producing, developing & selling various types of measuring instruments and testing equipment, such as temperature data logger, LCR meter, DC resistance tester (micro ohm meter), digital power meter, power supply, transformer tester, battery tester, programmable DC electronic load, charger, temperature controller, tachometer, high voltage signal-amplifier, power amplifier, etc.